0Items ৳ 0

Recently added item(s) ×

Your Cart is empty

Sivicaine Heavy Intraspinal

Intraspinal Injection
Renata Limited
Weight:
0.5%+8%

best Price:

? 30.11
? 30.11
(5's pack: ? 150.55)

Generic

Bupivacaine Hydrochloride + Dextrose

Indications

Bupivacaine Hydrochloride & Dextrose is indicated for- Bupivacaine is indicated for lower abdominal surgery (including Caesarean section), urological and lower limb, including hip surgery, lasting 1.5 to 3 hours. Bupivacaine are indicated for intrathecal (subarachnoid, spinal) anesthesia for surgical and obstetrical procedures. Bupivacaine produces motor blockade of the abdominal muscles makes the solution suitable for performance of abdominal surgery lasting 1.5-2 hours. The duration of motor blockade does not exceed the duration of analgesia.

Contraindications

Bupivacaine in Dextrose is contraindicated in patients with a known hypersensitivity to it or to any local anaesthetic agent of the amide type. The following conditions preclude the use of spinal anaesthesia: Severe hemorrhage, severe hypotension or shock and arrhythmias, such as complete heart block, which severely restrict cardiac output,Local infection at the site of proposed lumbar puncture ,Septicemia.

Side Effects

The adverse reaction profile for Bupivacaine is similar to those for other long acting local anesthetics administered intrathecally. Adverse reactions caused by the drug are difficult to distinguish from the physiological effects of the nerve block (e.g. decrease in blood pressure, bradycardia, temporary urinary retention), events caused directly (e.g. nerve trauma) or indirectly (e.g. epidural abscess) by the needle puncture or events associated to cerebrospinal leakage (eg. postdural puncture headache).

Pregnancy And Lactation

It is reasonable to assume that a large number of pregnant women and women of child-bearing age have been given Bupivacaine. No specific disturbances to the reproductive process have so far been reported, e.g. no increased incidence of malformations. It should be noted that the dose should be reduced in patients in the late stages of pregnancy With recommended doses, Bupivacaine enters breast milk in such small quantities that there is generally no risk of affecting the breast feed child. At maternal serum levels of up to 0.45 �g/ml produced by the epidural use of Bupivacaine for vaginal delivery, Bupivacaine could not be detected in breast milk during the first 24 hours after delivery (detection limit 0.02 �g/ml).

Therapeutic

Acute emergencies from local anaesthetics are generally related to high plasma levels encountered during therapeutic use or to underventilation (and perhaps apnea) secondary to upward extension of spinal anaesthesia. Hypotension is commonly encountered during the conduct of spinal anaesthesia due to relaxation of sympathetic tone, and sometimes, contributory mechanical obstruction of venous return.

Storage Conditions

Store in a cool and dry place. Protect from light.

Use the ↺ icon to reset the image
Use the ↺ icon to reset the image
Use the ↺ icon to reset the image
Use the ↺ icon to reset the image
Use the ↺ icon to reset the image
Use the ↺ icon to reset the image